Specifications and price | |
Brand: | Falcon Blue. |
Size: | 5 tons, 60,000 BTU. |
Electrical voltage: | 380-415 Volt Three Phys. |
Hertz: | 50 Hz. |
Electricity consumption: | 8.5 amps. |
Type: | Circulation system. |
Freon/gas: | R410a. |
Dimensions - (mm): | Length: 1127- Width: 358 - Height: 1240. |
Weight : | 120 kg. |
Control system: |
Digital control panel to control water temperature. |
The maximum temperature to reach: | It works to reduce the temperature from 48 degrees to (20) degrees achieved by the device. |
Installation location : |
On the rooftop tank or in the swimming pool. |
Warranty: | 4 years on the compressor only and one year on the rest of the other parts. |
Price: | 11,500/-QR, including supply and installation. Without the cost of extending electricity. |
The best Falcon water tank cooling device and the difference between Circulation and coil systemThe Falcon Water Tank chiller is one of best water tank cooling devices that cool the water in tanks using Freon gas quickly and efficiently, regardless of the water temperature, especially in the Arab Gulf countries that suffer hot summer weather, which affects the water in the tanks on roofs, making Its temperature is high, which hinders the use of water in daily activities that cannot be dispensed with, such as showering and washing. the solution lies in the Falcon water tank chiller
device, which is the best tank cooling device that works by the compressor on two systems, the Circulation system and the coil system to be able to get rid of the hot water at all times
The price of the best water tank cooling device for this water tank includes the price of the Falcon tank water cooling device with a size of 5 tons and installation on the water tank only and does not include the costs of electricity extensions and electrical connections, as the device needs a 32-amp switch separate from the household electrical circuit breakers to ensure that the compressor works properly.
Speaking on the warranty and guarantee, ARTEC Company provides a warranty on the compressor in the best water tank cooling devices for five years and one year on the rest of the parts with the availability of all original spare parts, maintenance, repair, supply and installation services provided by the ARTEC company’s staff, which includes engineers and technicians Specializing in maintenance and installation of tank water cooling systems, heaters and home filters.
The Falcon compressor to cool the tank water is the best water tank cooling devices, which solves the problem of hot water in tanks on roofs throughout the summer in addition to the fact that the Falcon compressor circuit system is a water cooler for ponds or swimming pools that cools the water outside the tank in the external cooling unit in which the cooling tank is located after it is withdrawn with the Circulation water pump, after which the water is quickly returned to the tank or pond through a recycling process, hot water is withdrawn from the pool and returned to cold water after it has lost its heat significantly.
The Falcon Circulation device continues the process of cooling the water of tanks or ponds and swimming pools until reaching the required temperature, which the user can specify according to his desire and need through the powerful Falcon devices that work with high efficiency to provide cold water in the summer for multiple home uses Iin addition to the ability to cool ponds and swimming pools water quickly and in high quality with automatic adjustment of the temperature determined by the user according to his need with the availability of multiple sizes suits all types and sizes of tanks, ponds and swimming pools.
Falcon tank water cooling device Circulation system is the first device specialized in cooling the water of tanks, ponds and swimming pools, where the device is placed next to tanks or ponds, and it is connected and begins to work after setting the required temperature in the automatic digital control panel, The device stops working as soon as the water temperature reaches the required temperature, which was previously set in the digital control panel, so that the device does not return to work unless the water temperature returns to high, then the device will start working automatically in order to make the set temperature always constant in the tank water and in order to The water never gets hot again. The device works similarly to the mechanism of wall air conditioners that have an internal and external device where it is set to the desired temperature and works automatically.
The Falcon compressor Circulation system is considered the best water tank cooling devices because it is a powerful device that can withstand the high-water temperature that may reach above 55 degrees Celsius and it consists of the following parts:
The Falcon Circulation Tank Chiller, the water tank cooler device that works by the most powerful and efficient Circulation pump, works according to the following steps:
The water tank cooler Falcon compressor is the best tank water cooling device thanks to the features it provides, which made it the number one choice for customers, and according to users’ experiences and evaluation, it has proven to be an effective and reliable device to solve the problem of high-water temperature in tanks, and these features include:
The Falcon Water Tank Cooler System Coil System works by Freon gas through a powerful compressor located in the device with an indicator showing the gas pressure in the compressor and a coil system that cools the water inside the tank by means of a cooling coil placed inside the tank, and this chilled coil works as a cold distributor. After a short time, the temperature of the entire tank becomes very low as desired and can be used for all the daily needs of the house.
The Falcon water tank cooler compressor coil system consists of the following elements:
The Falcon Coil tank water cooling device works by cooling the chilled coils that are placed inside the tank and are like a large piece of ice from which the cold is transferred to the water in the tank. The following is how the Falcon Coil tank cooler works:
Falcon water tank cooler coil system is the best water tank cooling device due to its strength and stability in performance in cooling tank water. It is one of the powerful and effective devices that provide cold water and cool it as quickly as possible, whatever the temperature of the water and whatever the working conditions. The Falcon Coil device also enjoys a five-year warranty on the compressor from ARTEC Company. The device is available in very multiple sizes from one ton to 5 tons to suit all types of tanks with the availability of original spare parts and periodic follow-up from the maintenance team to ensure the device has a longer life span and guarantees the efficiency of the device throughout the summer period.
Since the Falcon Coil device cools the water inside the tank, it has been made of completely safe materials, and all the materials made of it are environmentally friendly materials that are not degradable or changeable, to ensure the cleanliness and health of the water that you will receive with strength and continuity.
The Falcon compressor water chiller devices are similar in some specifications, but differ in some important main parts, and therefore the difference between the two devices can be arranged as follows:
The electrical voltage of the Falcon tank cooling device Circulation system, is the same that the Falcon coil system compressor works on, which is:
The specifications in which the tank water cooler Falcon Circulation differs mainly relate to the operation and method of performance, because Falcon Circulation water chiller works on cooling outside the tank in the external cooling unit and then returns the cold water to the tank after cooling and repeats the process quickly until the water in the tank reaches the temperature set on the control panel.
The tank cooler Falcon coil water chiller works to cool the tank through copper coils coated with an insulating material for safety factors and are placed inside the water tank and the two devices have the same operating specifications in terms of compressor cooling and Freon gas, they are also similar in the same electrical voltage that they work on, but the method of coil specifications is that it cools the water inside the tank after cooling it until it reaches a temperature below zero, so it becomes like a large piece of ice
But the Circulation system relies on cooling outside the tank by pulling the water pump that draws hot water from the tank to the cooling unit, and this is the point of difference, which leads to a difference in uses as the tank water cooling device Falcon Circulation water cooler is the appropriate device for use in cooling the water of tanks and ponds This is because it draws water from the pond by a circulation pump and cools it externally in the cooling tank inside the external cooling unit, As for the tank water cooling device falcon, the coil system is a device that is specific to tanks only and is not used to cool the water of ponds and swimming pools.
The choice between the two Falcon compressors Tank water cooler must be compatible with the family’s needs and the size of the tank. The ARTEC Company has provided the necessary maintenance for your Falcon compressor, by providing a team of highly trained and skilled engineers and technicians who work meticulously to maintain the Falcon compressor devices and extend their lifespan. The company offers suitable offers for wholesale orders and shops, as well as requests for large numbers of large buildings and institutions, as well as the maintenance team supports the user in terms of installation, operation, periodic follow-up and repair with providing original spare parts for the device with the possibility of replacement or repair during the warranty period, and the device enjoys permanent maintenance after the expiry Warranty period at reasonable prices accessible to all users.
The Falcon water chiller with its various systems provided customers with all the solutions they need to the problem of hot water in tanks, ponds and swimming pools, where water cooling devices are installed in tanks to work immediately with high efficiency and strength in performance and permanent stability in distributing coldness to water so that water is available to the same degree desired by the user at high speed.
The coil is made of copper and holds the refrigerated gas in its liquid form. When the compressor increases pressure on the gas, this causes the gas to condense into a liquid state, and when the cooled gas turns into a liquid state, the refrigerant releases the heat it contains.
Definitely not, Falcon Circulation and Falcon Coil tank water coolers are very economical in consuming electricity as they work on 220v-240v /50Hz single phase voltage.
The type of gas used in Falcon Circulation and Falcon Coil tank water coolers is R417A, which is used globally, environment-friendly and does not cause any side effects.
The required temperature in tank water coolers is controlled and adjusted through a digital display that contains a control panel that enables the user to set the desired temperature with high ease.